DY984N copper solvent extraction reagent

DY984N copper solvent extraction reagent


Request A Quote


Description
DY984N copper solvent extraction reagent is compound reagent, includes aldoxime 25%, ketoxime 25% and solvent oil 50%. It is not only has good extraction ability, also has good stripping ability, can avoid third phase happened, and raise the copper’s net transfer capacity, the copper net transfer capacity can arrive to 2.7 g/L.
DY984N copper solvent extraction reagent test result
DY984N copper solvent extraction reagent test result

Molecular formula: C16H25NO2 & C17H27NO2

Name: 2-hydroxy-5-nonylsalicylaldehyde oxime & 2-Hydroxy-5-nonyl ketoxime
CAS No.: 50849-47-3 & CAS: 59344-62-6
TYPE DY984N copper solvent extraction reagent
Appearance Brown oil liquid
Density (25°C) 0.91-0.93
Flash temperature ≥62°C (PMCC)
Solubility of copper-carried organic (25°C) ≥30 g/L Cu
Copper saturation capacity 10% (V/V) 5.1-5.4 g/L Cu
Extraction kinetics ≥95% (30s)
Extraction isothermal point (Organic) ≥4.4 g/L Cu
Extraction isothermal point (Aqueous) ≤1.6 g/L Cu
Phase Stripping time of extraction ≤70s
Stripping kinetics ≥95% (30s)
Stripping isothermal point (Organic) ≤1.7 g/L Cu
Stripping isothermal point (Aqueous) ≥32.7 g/L Cu
Stripping Phase time ≤80s
Copper Net Transfer 2.7 g/L Cu
Cu/Fe selectivity ≥2000

DY984N copper solvent extraction reagent can be used alone or mixed with LIX984N, LIX973N, M5640, M5774, CP-150 and N902 etc. any copper extractant. You can free to add our reagent to your using reagent in any ratio.

In practice, to produce one metric ton cathode copper, the consumption of Aldoxime will more than 10kg, but Compound Aldoxime & Ketoxime (DY984N copper solvent extraction reagent) will less than 5kg. The consumption of Compound Aldoxime and Ketoxime reagent will less than single Aldoxime 3-6kg.

DY984N copper solvent extraction reagent Cothode copper inspection report

Our engineer is operating a copper extraction plant, the consumption of DY984N copper solvent extraction reagent is 2 kg to produce one ton copper cathode. The purity of copper cathode can reach 99.9982%. The data as below:

DY984N copper solvent extraction reagent copper cathode

Please click here to view the operation video: https://www.youtube.com/watch?v=-mQ8iWH1LUo to understand how to do the laboratory test.

How to make sure our reagent is workable in your plant:
Do above laboratory separately to compare the extraction ability, phase separation time and situation with your using reagent; Take your using organic phase, mix with our organic (V/V, 1:1), then do above laboratory test to check the extraction ability, phase separation situation, and confirm whether it has untoward effect.

If above tests all be normal, it means that both reagents can be mixed to use together.

Control room of Deyuan

Deyuan's control roomISO certificate of Deyuan

Our metal extractants as below:

  1. P204 (D2EHPA or HDEHP) This is used for first step to remove impurity for laterite nickel ore.
  2. DY319 high efficiency nickel cobalt co-extraction extractant for battery recycle, can take out nickel and cobalt together from Lithium battery electrolyte.
  3. DY272 Nickel cobalt separation extractant, it can take cobalt out from nickel cobalt solution, then leave pure nickel.
  4. DY988N/DY973N/DY902/DY5640 copper solvent extraction reagent.
  5. P507 non-ferrous metal extractant for copper, zinc, cobalt-nickel, cadmium, gold-silver, platinum group metals, rare earths and so on.
  6. DY377 efficient nickel and diamond separation extractant.
  7. DY366 Scandium extractant.
  8. DY316 Lithium extractant.